Command:

show flash

Mode:

Router>
Router#


Syntax:

Class A Flash file systems

show flash-filesystem: [all | chips | filesys]

Class B Flash file systems

show flash-filesystem: [partition number] [all | chips | detailed | err | summary]

Class C Flash file systems

show flash-filesystem:

 


Syntax Description:

flash-filesystem

Flash memory file system (bootflash:, flash:, slot0:, slot1:,slavebootflash:, slaveslot0:, or slaveslot1:)

all

(Optional) On Class B Flash file systems, all shows complete information about Flash memory, including information about the individual ROM devices in Flash memory and the names and sizes of all system image files stored in Flash memory, including those that are invalid.

On Class A Flash file systems, all shows the following information:

  •  

  • The information displayed when no keywords are used.
  • The information displayed by the filesys keyword.
  • The information displayed by the chips keyword.

     

chips

(Optional) Shows information per partition and per chip, including which bank the chip is in plus its code, size, and name

filesys

(Optional) Shows the Device Info Block, the Status Info, and the Usage Info

detailed

(Optional) Shows detailed file directory information per partition, including file length, address, name, Flash memory checksum, computer checksum, bytes used, bytes available, total bytes, and bytes of system Flash memory

err

(Optional) Shows write or erase failures in the form of number of retries

partition number

(Optional) Shows output for the specified partition number

If you do not specify a partition in the command, the router displays output for all partitions. You can use this keyword only when Flash memory has multiple partitions.

summary

(Optional) Shows summary information per partition, including the partition size, bank size, state, and method by which files can be copied into a particular partition

You can use this keyword only when Flash memory has multiple partitions.

 


Command Description:

To display the layout and contents of a Flash memory file system, use the show EXEC command.

If Flash memory is partitioned, the command displays the requested output for each partition, unless you use the partition keyword.

The command also specifies the location of the current image.

To display the contents of boot Flash memory, use the show bootflash: command as follows:

Class A Flash file systems

  show bootflash [all | chips | filesys]

Class B Flash file systems

  show bootflash [partition number] [all| chips | detailed | err]

To display the contents of internal Flash memory, use the show flash command as follows:

Class A Flash file systems

  show flash [all | chips | filesys]

Class B Flash file systems

  show flash [partition number][all | chips | detailed | err | summary]

The show (Flash file system) command replaces the show flash devices command.

 


Examples:

The output of the show command depends on the type of Flash file system you select. Types include flash:, bootflash:, slot0:, slot1:, slavebootflash:, slaveslot0:, and slaveslot1:.

This section contains examples of output from show flash:.

 

Although the examples below use flash: as the Flash file system, you may also use the other Flash file systems listed above.

Class A Flash File System

The following three examples show sample output for Class A Flash file systems. The following table describes the fields shown in the output.

Table: show (Class A Flash File System) Field Descriptions

Field Description

#

File's index number

ED

Whether the file contains an error (E) or is deleted (D)

type

File's type (1 = configuration file, 2 = image file). The software displays these values only when the file's type is certain. When the file's type is unknown, the system displays unknown in this field.

crc

File's cyclic redundant check

seek

Offset into the file system of the next file

nlen

Length of the file's name

length

Length of the file itself

date/time

Date and time the file was created

name

File's name

The following is sample output from the show flash: command.

RouterA#show flash:

-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1   .. unknown  317FBA1B  4A0694   24  4720148 Aug 29 1997 17:49:36 hampton/nitro/c7200-j-mz
2   .. unknown  9237F3FF  92C574   11  4767328 Oct 01 1997 18:42:53 c7200-js-mz
3   .D unknown  71AB01F1 10C94E0   10  7982828 Oct 01 1997 18:48:14 rsp-jsv-mz
4   .D unknown  96DACD45 10C97E0    8      639 Oct 02 1997 12:09:17 the_time
5   .. unknown  96DACD45 10C9AE0    3      639 Oct 02 1997 12:09:32 the_time
6   .D unknown  96DACD45 10C9DE0    8      639 Oct 02 1997 12:37:01 the_time
7   .. unknown  96DACD45 10CA0E0    8      639 Oct 02 1997 12:37:13 the_time

3104544 bytes available (17473760 bytes used)
 

The following is a sample of output from the show flash: chips command:

RouterA#show flash: chips


******** Intel Series 2+ Status/Register Dump ********

ATTRIBUTE MEMORY REGISTERS:
  Config Option Reg (4000): 2
  Config Status Reg (4002): 0
  Card Status   Reg (4100): 1
  Write Protect Reg (4104): 4
  Voltage Cntrl Reg (410C): 0
  Rdy/Busy Mode Reg (4140): 2

COMMON MEMORY REGISTERS: Bank 0
  Intelligent ID Code  : 8989A0A0
  Compatible Status Reg: 8080
  Global     Status Reg: B0B0
  Block Status Regs:
    0  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    8  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    16 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    24 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0

COMMON MEMORY REGISTERS: Bank 1
  Intelligent ID Code  : 8989A0A0
  Compatible Status Reg: 8080
  Global     Status Reg: B0B0
  Block Status Regs:
    0  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    8  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    16 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    24 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0

COMMON MEMORY REGISTERS: Bank 2
  Intelligent ID Code  : 8989A0A0
  Compatible Status Reg: 8080
  Global     Status Reg: B0B0
  Block Status Regs:
    0  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    8  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    16 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    24 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0

COMMON MEMORY REGISTERS: Bank 3
  Intelligent ID Code  : 8989A0A0
  Compatible Status Reg: 8080
  Global     Status Reg: B0B0
  Block Status Regs:
    0  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    8  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    16 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    24 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0

COMMON MEMORY REGISTERS: Bank 4
  Intelligent ID Code  : 8989A0A0
  Compatible Status Reg: 8080
  Global     Status Reg: B0B0
  Block Status Regs:
    0  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    8  :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    16 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0
    24 :  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0  B0B0

 

The following is a sample of output from the show flash: filesys command:

RouterA#show flash: filesys


-------- F I L E   S Y S T E M   S T A T U S --------
  Device Number = 0
DEVICE INFO BLOCK:
  Magic Number          = 6887635   File System Vers = 10000    (1.0)
  Length                = 1400000   Sector Size      = 20000
  Programming Algorithm = 4         Erased State     = FFFFFFFF
  File System Offset    = 20000     Length = 13A0000
  MONLIB Offset         = 100       Length = C730
  Bad Sector Map Offset = 1FFEC     Length = 14
  Squeeze Log Offset    = 13C0000   Length = 20000
  Squeeze Buffer Offset = 13E0000   Length = 20000
  Num Spare Sectors     = 0
    Spares:
STATUS INFO:
  Writable
  NO File Open for Write
  Complete Stats
  No Unrecovered Errors
  No Squeeze in progress
USAGE INFO:
  Bytes Used     = 10AA0E0  Bytes Available = 2F5F20
  Bad Sectors    = 0       Spared Sectors  = 0
  OK Files       = 4       Bytes = 90C974
  Deleted Files  = 3       Bytes = 79D3EC
  Files w/Errors = 0       Bytes = 0

Class B Flash File Systems

The table below describes fields in the sample output for Class B Flash file systems

Table: show (Class BFlash File System) all Fields

Field Description

addr

Address of the file in Flash memory

available

Total number of bytes available in Flash memory

Bank

Bank number

Bank-Size

Size of bank in bytes

bytes used

Total number of bytes used in Flash memory

ccksum

Computed checksum

Chip

Chip number

Code

Code number

Copy-Mode

Method by which the partition can be copied to:

  •  

  • RXBOOT-MANUAL indicates a user can copy manually by reloading to the boot ROM image.
  • RXBOOT-FLH indicates user can copy via Flash load helper.
  • Direct indicates user can copy directly into Flash memory.
  • None indicates that it is not possible to copy into that partition.

     

fcksum

Checksum recorded in Flash memory

File

Number of the system image file. If no filename is specified in the boot system flash command, the router boots the system image file with the lowest file number.

Free

Number of bytes free in partition

Length

Size of the system image file (in bytes)

Name

Name of chip manufacturer and chip type

Name/status

Filename and status of a system image file. The status [invalidated] appears when a file has been rewritten (recopied) into Flash memory. The first (now invalidated) copy of the file is still present within Flash memory, but it is rendered unusable in favor of the newest version. The [invalidated] status can also indicate an incomplete file that results from the user abnormally terminating the copy process, a network timeout, or a Flash memory overflow.

Partition

Partition number in Flash memory

Size

Size of partition in bytes or size of chip

State

State of the partition. It can be one of the following values:

  •  

  • Read-Only indicates the partition that is being executed from.
  • Read/Write is a partition that can be copied to.

     

System flash directory

Flash directory and its contents

total

Total size of Flash memory, in bytes

Used

Number of bytes used in partition


The following is a sample of output from the show flash: command:

RouterB> show flash:


System flash directory:
File  Length   Name/status
  1   4137888  c3640-c2is-mz.Feb24
[4137952 bytes used, 12639264 available, 16777216 total]
16384K bytes of processor board System flash (Read/Write)\
 

The following example shows detailed information about the second partition in internal Flash memory:

RouterB#show flash: partition 2


System flash directory, partition 2:
File  Length   Name/status
  1   1711088  dirt/images/c3600-i-mz
[1711152 bytes used, 15066064 available, 16777216 total]
16384K bytes of processor board System flash (Read/Write)
 

The following is a sample of output from the show flash: all command:

RouterB> show flash: all

Partition   Size    Used      Free      Bank-Size  State          Copy Mode
  1        16384K   4040K    12343K     4096K      Read/Write     Direct

System flash directory:
File  Length   Name/status
        addr      fcksum  ccksum
  1   4137888  c3640-c2is-mz.Feb24
        0x40      0xED65  0xED65
[4137952 bytes used, 12639264 available, 16777216 total]
16384K bytes of processor board System flash (Read/Write)

   Chip    Bank    Code      Size      Name
    1      1       01D5      1024KB    AMD   29F080
    2      1       01D5      1024KB    AMD   29F080
    3      1       01D5      1024KB    AMD   29F080
    4      1       01D5      1024KB    AMD   29F080
    1      2       01D5      1024KB    AMD   29F080
    2      2       01D5      1024KB    AMD   29F080
    3      2       01D5      1024KB    AMD   29F080
    4      2       01D5      1024KB    AMD   29F080
    1      3       01D5      1024KB    AMD   29F080
    2      3       01D5      1024KB    AMD   29F080
    3      3       01D5      1024KB    AMD   29F080
    4      3       01D5      1024KB    AMD   29F080
    1      4       01D5      1024KB    AMD   29F080
    2      4       01D5      1024KB    AMD   29F080
    3      4       01D5      1024KB    AMD   29F080
    4      4       01D5      1024KB    AMD   29F080


The following is a sample of output from the show flash: all command on a router with Flash memory partitioned:

Router#show flash: all


System flash partition information:
Partition   Size    Used       Free     Bank-Size     State         Copy-Mode
    1       4096K    3459K     637K     4096K         Read Only     RXBOOT-FLH
    2       4096K    3224K     872K     4096K         Read/Write    Direct

System flash directory, partition 1:
File     Length     Name/status
        addr     fcksum     ccksum
  1     3459720     master/igs-bfpx.100-4.3
        0x40     0x3DE1     0x3DE1
[3459784 bytes used, 734520 available, 4194304 total]
4096K bytes of processor board System flash (Read ONLY)

   Chip    Bank     Code      Size      Name
    1      1        89A2      1024KB    INTEL 28F008SA
    2      1        89A2      1024KB    INTEL 28F008SA
    3      1        89A2      1024KB    INTEL 28F008SA
    4      1        89A2      1024KB    INTEL 28F008SA
Executing current image from System flash [partition 1]

 System flash directory, partition2:
File     Length     Name/status
        addr     fcksum     ccksum
  1     3224008     igs-kf.100
        0x40     0xEE91     0xEE91
[3224072 bytes used, 970232 available, 4194304 total]
4096K bytes of processor board System flash (Read/Write)

   Chip    Bank     Code      Size      Name
    1      2        89A2      1024KB    INTEL 28F008SA
    2      2        89A2      1024KB    INTEL 28F008SA
    3      2        89A2      1024KB    INTEL 28F008SA
    4      2        89A2      1024KB    INTEL 28F008SA

The following is a sample of output from the show flash: chips command:

RouterB>show flash: chips

16384K bytes of processor board System flash (Read/Write)

   Chip    Bank    Code      Size      Name
    1      1       01D5      1024KB    AMD   29F080
    2      1       01D5      1024KB    AMD   29F080
    3      1       01D5      1024KB    AMD   29F080
    4      1       01D5      1024KB    AMD   29F080
    1      2       01D5      1024KB    AMD   29F080
    2      2       01D5      1024KB    AMD   29F080
    3      2       01D5      1024KB    AMD   29F080
    4      2       01D5      1024KB    AMD   29F080
    1      3       01D5      1024KB    AMD   29F080
    2      3       01D5      1024KB    AMD   29F080
    3      3       01D5      1024KB    AMD   29F080
    4      3       01D5      1024KB    AMD   29F080
    1      4       01D5      1024KB    AMD   29F080
    2      4       01D5      1024KB    AMD   29F080
    3      4       01D5      1024KB    AMD   29F080
    4      4       01D5      1024KB    AMD   29F080
 

The following is a sample of output from the show flash: detailed command:

RouterB>show flash: detailed


System flash directory:
File  Length   Name/status
        addr      fcksum  ccksum
  1   4137888  c3640-c2is-mz.Feb24
        0x40      0xED65  0xED65
[4137952 bytes used, 12639264 available, 16777216 total]
16384K bytes of processor board System flash (Read/Write)
 

The following is a sample of output from the show flash: err command:

RouterB>show flash: err


System flash directory:
File  Length   Name/status
  1   4137888  c3640-c2is-mz.Feb24
[4137952 bytes used, 12639264 available, 16777216 total]
16384K bytes of processor board System flash (Read/Write)

   Chip    Bank    Code      Size      Name                erase  write
    1      1       01D5      1024KB    AMD   29F080      0      0
    2      1       01D5      1024KB    AMD   29F080      0      0
    3      1       01D5      1024KB    AMD   29F080      0      0
    4      1       01D5      1024KB    AMD   29F080      0      0
    1      2       01D5      1024KB    AMD   29F080      0      0
    2      2       01D5      1024KB    AMD   29F080      0      0
    3      2       01D5      1024KB    AMD   29F080      0      0
    4      2       01D5      1024KB    AMD   29F080      0      0
    1      3       01D5      1024KB    AMD   29F080      0      0
    2      3       01D5      1024KB    AMD   29F080      0      0
    3      3       01D5      1024KB    AMD   29F080      0      0
    4      3       01D5      1024KB    AMD   29F080      0      0
    1      4       01D5      1024KB    AMD   29F080      0      0
    2      4       01D5      1024KB    AMD   29F080      0      0
    3      4       01D5      1024KB    AMD   29F080      0      0
    4      4       01D5      1024KB    AMD   29F080      0      0

Refer to tables above for a description of the fields. The show flash: err command also displays two extra fields, erase and write. The erase field indications the number of erase errors. The write field indicates the number of write errors.
The following is a sample of output from the show flash summary command on a router with Flash memory partitioned. The partition in the Read Only state is the partition from which the Cisco IOS image is being executed.
Router#show flash summary


System flash partition information:
Partition   Size     Used      Free    Bank-Size   State       Copy-Mode
    1       4096K    2048K     2048K   2048K       Read Only   RXBOOT-FLH
    2       4096K    2048K     2048K   2048K       Read/Write  Direct


Misconceptions:

None

Related Commands:
None

� Cisco Systems, Inc. 2001, 2002, 2003